Description
Allows for use in 2″ x 8″ construction.
Aluminum Construction: Single Wall Housing.
California Title 24 (JA8-2016-E).
SPECIFICATIONS :
Wattage 9W
Voltage 120V
Dimmable Triac/ELV
Wet Location Listed
Construction:
IC Rated for Direct Contact with Insulation.
Designed for use in 2/12 to 6/12 sloped ceiling.
Housing adjusts to accommodate up to 1 1/4” ceiling thickness.
Aluminum housing for greater heat dissipation. Stamped galvanized steel frame.
Installation: Designed for ceiling plenums where 2×8 joists or taller are used. High strength hanger bars can easily be nailed to joists. Template for hole cutout is provided with each housing. Suitable for T-grid and drop ceiling applications. See installation sheet for detailed information.
Junction Box: Positioned to accommodate straight conduit runs. Seven 1/2” trade size conduit knockouts and four pry-out knockout slots for easy romex installation.
Hanger Bars: Pre-installed hanger bars with True Nail easy installation in regular lumber, engineered lumber, and Laminated Beams. Integral T-bar slots for easy installation in T-Bars. Spans up to 24″ and can be repositioned 90°. Score lines allow for tool-free hanger bar size reduction. Integral leveling flange allows for single-person installation while aligning the housings with the joists.
Electrical:
Rated for 120V or 277V input.
For 277V step down to 120V housing consult factory.
Listings:
UL Listed for Damp Location.
UL Listed for Direct Contact with Insulation and Combustible Material.
UL Listed for Feed Through.
AirTight Per ASTM E-283.
California Title 24 (JA8-2016-E).
Warranty: ELCO Products are built to last. 5-year Limited warranty.